簡(jiǎn)要描述:阻抗分析儀6500可串/并聯(lián)電路,或兩極式,可當(dāng)標(biāo)準(zhǔn)LCR電表使用,適用于電容器、電感器、電阻器、變壓器、陶瓷諧振器
產(chǎn)品分類
Product Category相關(guān)文章
Related Articles詳細(xì)介紹
產(chǎn)品詳情:
阻抗分析儀6500
6500
功能 | 6505B | 6510B | 6515B | 6520B | 6530B | 6550B | 65120B | ||||||||||||||||||||||||
頻率范圍 | 20Hz–5MHz | 20Hz–10MHz | 20Hz–15MHz | 20Hz–20MHz | 20Hz–30MHz | 20Hz–50MHz | 20Hz–120MHz | ||||||||||||||||||||||||
基本精確度 | 0.05% | ||||||||||||||||||||||||||||||
頻率精確度 | ±0.005% | ||||||||||||||||||||||||||||||
阻抗分析儀6500量測(cè)參數(shù) | Z, Ø, L, C, R, Q, D, Y, G, B, X | ||||||||||||||||||||||||||||||
輸出 | 10mV to 1V rms, 200uA to 20mA rms | ||||||||||||||||||||||||||||||
顯示格式 | 串/并聯(lián)電路,或兩極式 | ||||||||||||||||||||||||||||||
圖形分析模式 | 任選兩種參數(shù)依頻率, 驅(qū)動(dòng)值及直流偏壓源掃描 | ||||||||||||||||||||||||||||||
電表模式 | 可當(dāng)標(biāo)準(zhǔn)LCR電表使用 | ||||||||||||||||||||||||||||||
待測(cè)元件連接 | 可通過面板的BNC接頭來(lái)實(shí)現(xiàn)倆端,三端或四埠的連接以及可能的接地狀況.備有許多的可選附件以供不同的測(cè)試需要. | ||||||||||||||||||||||||||||||
量測(cè)精度 | 消耗因素: ±0.0005(1+D*D2) 品質(zhì)因素: ±0.05%(Q + 1/Q) 電容/電感/阻抗: ± 0.05 | ||||||||||||||||||||||||||||||
| The 6500B series of Precision Impedance Analyzers provide precise and fast testing of components at frequencies up to 120 MHz. Basic measurement accuracy is ±0.05% making the instruments the best in the class. The accuracy and versatility makes the precision analyzers the ideal choice for many different tasks and applications including passive component design, dielectric material characterisation and manufacturing test. Engineers need to evaluate component characteristics at high frequencies with high levels of accuracy. The 65120B 120 MHz Precision Impedance Analyzer is therefore ideal for many demanding tasks, combining accuracy and ease of use at an affordable price. If a frequency range up to 120 MHz is not required then other models are available. The 6505B 5MHz instrument is the entry level model in the range. |
| |||||||||||||||||||||||||||||
| High measurement accuracy |
| |||||||||||||||||||||||||||||
| Capacitance, inductance and impedance basic accuracy is an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%. |
| |||||||||||||||||||||||||||||
| Graphical sweep of components |
| |||||||||||||||||||||||||||||
| The 6500B series of Precision Impedance Analyzers are highly accurate high frequency component analyzers with a host of useful features.
|
| |||||||||||||||||||||||||||||
|
| ||||||||||||||||||||||||||||||
| Variable drive and bias levels |
| |||||||||||||||||||||||||||||
| AC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments. |
| |||||||||||||||||||||||||||||
| External control |
| |||||||||||||||||||||||||||||
| The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes. An Ethernet interface similarly allows the instrument to be controlled and to send out data - allowing it to be integrated into many test environments. |
| |||||||||||||||||||||||||||||
| Wide range of interfaces |
| |||||||||||||||||||||||||||||
| An external monitor or projector may be connected to the instrument. The ability to provide a large screen display is invaluable in production environments or for teaching and training. Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation. |
| |||||||||||||||||||||||||||||
| Data storage and retrieval |
| |||||||||||||||||||||||||||||
| All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard). |
| |||||||||||||||||||||||||||||
| Setup data |
| |||||||||||||||||||||||||||||
| Up to 20 instrument setups may be stored locally for each mode. |
| |||||||||||||||||||||||||||||
| Bin handling |
| |||||||||||||||||||||||||||||
| The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits. |
| |||||||||||||||||||||||||||||
| Printer outputs |
| |||||||||||||||||||||||||||||
| Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via Ethernet connection. |
| |||||||||||||||||||||||||||||
| Component connections |
| |||||||||||||||||||||||||||||
| Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential. |
| |||||||||||||||||||||||||||||
| Protection against charged capacitors |
| |||||||||||||||||||||||||||||
| High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors. |
| |||||||||||||||||||||||||||||
| Comprehensive and precise component tests at higher frequencies |
| |||||||||||||||||||||||||||||
| The 6500B series capabilities are best summarised by “Comprehensive and precise component tests at higher frequencies”. The instruments are the perfect solution for those who have demanding component measurement needs. |
| |||||||||||||||||||||||||||||
| Technical Specifications: |
| |||||||||||||||||||||||||||||
|
|
| |||||||||||||||||||||||||||||
| General Data: |
| |||||||||||||||||||||||||||||
|
|
| |||||||||||||||||||||||||||||
產(chǎn)品咨詢
微信掃一掃